Current Audio SB80 Wartungshandbuch Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 70
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
Hea
Hea
v
v
y dut
y dut
y and explosion-proof stations
y and explosion-proof stations
LBB 7089/40
Heavy duty master station
LBC 3490/10
Loudspeaker horn, 16 ohm
Front plate in blank aluminium enshrouds
polyurethane elastomere sealing caps cover-
ing the selection and function buttons.
Controls for simplex mode and system
functions. +/- buttons for accepting and
rejecting certain functions.
Volume and privacy must be pre-set inter-
nally in each station.
A call tone and a pilot lamp indicate con-
nection.
A heavy duty handset kit may be fitted for
use in noisy areas or for confidential calls.
External call signal may be rendered
through separate bell or lamp giving a sig-
nal in areas with high noise level.
The heavy duty master station has a built-
in application kit as standard which
requires external power either locally or
centrally.
When not used for external signalling
the application kit can be used for open-
ing doors.
This 10 ½" x 7" speaker is designed for use
with the heavy duty master station either
outdoors or in industrial buildings and
yards.
The horn is splash and dust-proof, made
from aluminium, and is supplied with an
adjustable mounting bracket.
Technical data: LBB 7089/40 LBC 3490/10
Dimensions (wxhxd) in mm/inch: 160x260x106/6.3x10.2x4.2
Weight, net, in kg/lb: 2.7/5.9
Environmental conditions, category: T4
IP code: 40 (front access)
Approval: CE
Supply voltage : 36 V d.c.
At the station, idle <10 V d.c.
At the station, in operation 24 - 40 V d.c./18 - 30 V a.c.
Current consumption
At the station, idle <0.3 mA
At the station, in operation 25 - 38 mA
From unregulated 30 V power 350 mA average at 16 W
From regulated 36 V power 800 mA max.
Output power (continuous/peak): 90/300 mW
Cabling:
Extension line 2-wire
The heavy duty master station is for use in
severe indoor or outdoor applications.
The station is especially designed for with-
standing rigorous environments including
temperature extremes and dusty or corro-
sive atmospheres.
Large keys provide for convenient opera-
tion even when wearing protective gloves.
Built-in microphone and external loud-
speaker horn enable maximum adaptation
to the local acoustical situation.
The heavy duty master station is delivered
as a wall mount unit constructed from
corrosion-proofed wide gauge aluminium
and with an orange colour finish.
Overall length: 276/10.9
1.25/2.8
Rated impedance: 16 ohm
65
Eff. freq. range (-10dB): 410- 3900 Hz
Power handling capacity: 10 W
Seitenansicht 9